No Water After a Power Outage? 7 Calm Well Checks
Description
No water after the power comes back? On a private well, the fix is usually a few minutes away. This calm checklist walks the same path as our water filtration video, from the pump to the tap, in the order a pump troubleshooting guide would: power to the pump, the pressure switch, the tank gauge, frozen lines, the generator path, when to call a pro, and making sure the water is safe. Then one number to keep on hand: a gallon of stored water per person, per day. Key numbers: one common 20-gallon pressure tank delivers only about 6 gallons between 30 and 50 psi. A low-pressure cutoff switch locks the pump off 10 psi below the cut-in (about 20 psi on a 30/50 switch). Tank air pre-charge is 2 psi below the cut-in. Franklin Electric's table calls for at least a 2 kW generator for a half-horsepower submersible pump (about 3 kW for a two-wire pump). Earlier in this series: - Well water filtration, from the pump to the tap: https://youtu.be/K_GIwos0rog - Sizing a home battery bank: https://youtu.be/LhvJhRbScqQ - Backup generators explained: https://youtu.be/GoZpVjb6Dw4 Chapters 0:00 Intro 0:27 Why the water stops 1:07 Check 1: Power to the pump 1:44 Check 2: The pressure switch 2:30 Check 3: Read the tank gauge 3:11 Check 4: Frozen lines 4:04 Check 5: The generator path 4:50 Check 6: When to call a pro 5:36 Check 7: Safe water after restore 6:25 Stored water: the number to keep on hand 7:05 Recap and what's next Sources: U.S. EPA (private wells; wells after a flood), CDC (well disinfection after an emergency, drinking water advisories, emergency water supply), Ready.gov, American Red Cross (frozen pipes), Square D Pumptrol pressure switch guide, Amtrol Well-X-Trol tank documentation, Franklin Electric submersible motor manual, and Portland General Electric's well outage guidance. Safety: The pressure switch, control box and pump circuit carry 240 volts whenever the breaker is on. Use the lever on the outside of the switch, keep covers on, and keep hands and floors dry. Wiring, panel work, transfer switches and generator connections are jobs for a licensed electrician. Tank pre-charge checks are best left to a licensed pro. If floodwater reached your well, don't drink the water until it has been disinfected and tested, and have the wiring checked before the pump goes back on. This video is general information. It doesn't replace a licensed well contractor, electrician or your local health department. Footage: Pexels, used under the Pexels License. Thanks to Kostiantyn Zavhorodnii, Lukáš Vaňátko, Connor Scott McManus, Evgenij Mikhailov, Tom Fisk and the other Pexels creators. Diagrams and animation are original. #WellWater #PowerOutage #Homestead
8:24A Hand Pump for Shallow Water sourcesEngineer775247K views
3:07This water harvester can turn desert air into drinkable waterUC Berkeley340K views
8:56Making Water after Rainwater Collection FailGridlessness117K views
3:56CHEAP and EASY, Emergency Well Pump Requires No ElectricityProfitFromPlanning485K views
14:35One Power Outage Away From No WaterThe Ready Life2K views
8:03Is One Case of Bottled Water Enough for a Power Outage?Better Than Nothing Prepping8 views
10:13How to Set Up Water and Energy Security for a Long-Term Power OutageVergePermaculture4.8K views
19:27Your Tap Water Looks Clean. It Could Put You in the Hospital.Until The Lights Return32 views
12:58Water Storage 101: Power OutagePalmetto Prepared243 views
12:38Purifying Water - Filters vs Boiling vs Chemicals. What I do to Make Water Safe for Drinking.Simon, a bloke in the woods182K views
7:06How to Use Water Storage in a Power OutageDirtpatcheaven1.1K views
18:23Grid Down. Power Outage Water Solution. No Power Needed: Installing the Excelsior Hand PumpON Three25.2K views
13:02How Long Your Tap Water Stays Safe After a Power OutageSketchHazard184 views
11:53Cool Water for a Hot HomesteadEngineer77511.8K views